Eurocode Compliant & International Delivery

Steel Frame Healthcare Facilities & Medical Clinics

Precision engineered medical steel structures designed to meet strict clinical hygiene, acoustic isolation, and heavy medical equipment load standards.

Request Project Quote Quick WhatsApp Inquiry
Eurocode 3 & 8 Certified Engineering
EN 1090-2 Factory Quality Control
40ft HC Container Packing & Flat-Pack Export
100% Bolted Field Assembly (Zero Site Welding)

Engineering Quick Specifications

Eurocode 3 Ready
Clear Span Range Modular clinical grids of 3.6m and 7.2m with reinforced diagnostic zones
Height & Storey Range 1 to 3 storeys
Structural Steel Quality S350GD Galvanized Framing + Antibacterial Cladding Layers
Available Delivery Scope Supply Only • Supply + Supervision
Ideal Project Types Community health clinics, Diagnostic imaging centers (MRI/CT ready floors), Emergency triage facilities, Dialysis and rehabilitation centers

Engineering Overview & Structural Scope

SerBuild engineered Healthcare & Medical Clinics systems are custom designed around project-specific loads, spans, and building geometry. We eliminate intermediate columns to maximize internal usable floor area while maintaining rigorous structural safety factors under European Eurocodes.

All structural components are precision fabricated in our factory in Türkiye using automated CNC roll-forming and robotic welding lines, pre-punched for 100% bolted field assembly without on-site hot work.

Every element is permanently coded and bundled according to strict 3D container packing algorithms, ensuring rapid, sequential offloading on your job site.

Key Engineering Advantages

  • Vibration-damped structural floor assemblies tailored for sensitive medical diagnostic equipment
  • Smooth antimicrobial interior wall linings with seamless floor coving integration
  • Pre-engineered MEP raceways for medical gas, HVAC HEPA filtration, and emergency backup power

Structural Skeletons & Envelope Integration

Engineered for durability, wind resistance, and zero thermal bridging.

Primary Structural Steel

Hot-rolled structural sections (S355JR / S355J2) or high-tensile cold-formed galvanized C/U sections (S350GD + Z275). Shot-blasted to SA 2.5 standard with certified corrosion protection.

Purlins, Girts & Bracing

Continuous cold-formed Z and C purlins with overlapping lap joints for maximum structural stiffness, combined with high-tensile threaded rod or cable cross-bracing.

Cladding & Thermal Barrier

Compatible with PIR/PUR sandwich panels (40mm–200mm), non-combustible rockwool panels (REI 120), or architectural fiber cement rainscreens with integrated thermal break strips.

Eurocode Load Assessment

Every building is calculated using site-specific meteorological and seismic coordinates:

  • Snow Load (EN 1991-1-3): Calculated for ground snow loads up to 4.5 kN/m² with drift accumulations.
  • Wind Load (EN 1991-1-4): Verified for peak gusts, terrain roughness categories 0 to IV, and coastal pressures.
  • Seismic Design (EN 1998): Ductile energy dissipation with structural behavior factor q up to 3.0.

Foundation Reactions & Anchor Interface

We deliver complete foundation engineering documentation for your local civil engineer: anchor bolt coordinates, reactions tables, and pre-welded positioning cages.

  • Anchor Bolt Layout Plans: Exact coordinates, diameters, and embedment depths.
  • Reaction Force Tables: Maximum axial compression, tension uplift, shear, and overturning moments.
  • Anchor Hardware: Pre-welded anchor bolt positioning cages supplied with the kit.

🛠️ Factory Quality Control & Site Assembly Process

01
Anchor Verification

Laser verification of cast-in anchor bolts against SerBuild foundation coordinates.

02
Frame Erection

Columns and rafters lifted with mobile crane and secured with Grade 8.8/10.9 bolts.

03
Purlin & Bracing

Continuous galvanized Z-purlins, wall girts, and high-tensile cross-bracing cables installed.

04
Cladding & Seal

PIR sandwich panels, flashings, and gutters fastened with airtight sealants.

Relevant Project References

Real-world evidence of precision Eurocode engineering, containerized export, and on-site assembly execution.

Split, Croatia Supply + Supervision

266 m² Contemporary Light Gauge Steel Villa in Split, Croatia

Challenge: Severe coastal bora wind gusts (up to 180 km/h) and high seismic ground acceleration in the Adriatic coastal z...

266 m² (2,863 sq ft) Case Study →
Bavaria, Germany Supply Only (Kit Package)

1,800 m² Clear-Span Steel Logistics Warehouse in Bavaria, Germany

Challenge: 30-meter column-free clear span required to maximize high-bay pallet racking, integrated with a 10-ton overhea...

1,800 m² (19,375 sq ft) Case Study →
Lyon, France Supply + Supervision

4,500 m² Logistics Distribution Center in Lyon, France

Challenge: 12 integrated loading docks, high internal clearance of 12 meters, strict NF EN French Eurocode compliance, an...

4,500 m² (48,438 sq ft) Case Study →

Frequently Asked Questions

Detailed answers to technical, manufacturing, export, and on-site assembly questions.

We engineer clear spans from 12 meters up to 60+ meters in rigid portal frames and up to 90+ meters in heavy tubular space trusses, providing unobstructed floor space for high-bay racking and logistics.

Yes. We design structural columns with integrated crane brackets and supply certified crane runway beams engineered for overhead cranes ranging from 5 tons up to 30+ tons, calculated according to dynamic fatigue standards (EN 1993-6).

No. All SerBuild structural steel elements and cold-formed purlins are 100% pre-drilled and fabricated in our factory. On-site assembly is completed entirely with high-strength structural bolts (Grade 8.8 and 10.9), eliminating hot-work on site.

Our frames are compatible with all standard envelope options, including PIR/PUR insulated sandwich panels (40mm to 200mm), non-combustible stone wool firewalls, single-skin trapezoidal profile sheets, and daylighting polycarbonate panels.

Yes. Every project includes a comprehensive foundation interface package specifying exact anchor bolt locations, base plate dimensions, and foundation reaction forces (vertical, horizontal shear, and overturning moments).

Request an Engineered Steel Building Proposal

Submit your project dimensions, drawings or requirements for an engineering review and itemized quote within 24–48 hours.

1
2
3
4
5

Step 1: What type of steel building are you planning?

Step 2: Project Location & Target Dimensions

Step 3: Preferred Delivery Scope

Step 4: Project Schedule & Readiness

Step 5: Contact & Drawing Upload

Instant WhatsApp Consultation