Engineered cold-formed steel C-joists and open-web floor trusses designed for high acoustic isolation, vibration damping, and long clear spans.
Precision manufacturing parameters, steel grades, connection hardware, and performance metrics.
How vertical gravity, lateral wind, and seismic forces are dissipated through our engineered framing.
Floor live loads (2.0 to 7.5 kN/m²) are carried by deep cold-formed C-joists or open-web steel floor trusses spanning up to 8.5 meters clear. Dynamic footfall vibrations are suppressed through engineered solid steel web stiffeners and continuous underside drywall ceiling decoupling.
Horizontal floor diaphragm action is established via structural floor boarding (oriented strand board or cement-bonded particle board) screwed directly to the joist top flanges, transferring seismic and wind shear forces into perimeter load-bearing walls.
Impact acoustic performance achieves Ln,w < 48 dB through resilient acoustic underlays and wet or dry screed floating floor assemblies. Infilled acoustic mineral wool dampens airborne sound transmission across residential levels (Rw > 56 dB).
Fully verified structural calculations meeting European, British, and international building codes.
Bending moment and shear capacity verification of thin-walled joists with service cutouts.
Footfall dynamic response and deflection checks strictly limited to L/450 or 5mm max.
Laboratory-verified weighted impact sound reduction for multi-family party floors.
REI 60 to REI 90 load-bearing fire resistance with double ceiling fireboard linings.
From 3D Tekla BIM modeling to automated roll-forming, container packing, and on-site bolted erection.
Parametric spacing and cutout alignment for HVAC ductwork and plumbing runs.
Precision roll-forming of 150mm–300mm depth joists with pre-cut tabs and end flanges.
Factory assembled into 2.4m x 7.5m floor cassettes for instant crane drop-in or flat-pack shipment.
Fast interlocking into wall perimeter track channels with heavy-duty structural screws.
Why civil engineers, architects, and international contractors specify this SerBuild technology.
Steel joists eliminate floor creaks, seasonal shrinkage, and joist warping permanently.
Open-web and punched C-joists conceal ductwork and pipes within floor depths.
Long clear spans remove the necessity for intrusive interior load-bearing walls.
Acoustic floating floors achieve Ln,w < 48 dB impact and Rw > 56 dB airborne ratings.
Explore the primary architectural and industrial building types utilizing this structural system.
Clear-span halls up to 60m+ span with optimized eave heights and overhead crane integration.
View Industrial →Modern 1 to 6-storey residential structures with superior acoustic privacy and seismic safety.
View Residential →Heavy-duty framing for corporate offices, retail complexes, and mission-critical IT data centers.
View Commercial →Corrosion-resistant equestrian arenas, grain storage halls, and ventilated livestock facilities.
View Agricultural →Complete technical documentation and models supplied for municipal permitting and construction.
Real-world evidence of precision Eurocode engineering, containerized export, and on-site assembly execution.
Challenge: Severe coastal bora wind gusts (up to 180 km/h) and high seismic ground acceleration in the Adriatic coastal z...
Challenge: 30-meter column-free clear span required to maximize high-bay pallet racking, integrated with a 10-ton overhea...
Challenge: 12 integrated loading docks, high internal clearance of 12 meters, strict NF EN French Eurocode compliance, an...
Detailed answers to technical, manufacturing, export, and on-site assembly questions.
SerBuild designs and manufactures light gauge steel (LGSF) and heavy structural steel buildings for residential developments, industrial warehouses, manufacturing factories, aircraft hangars, commercial offices, and agricultural halls.
Yes. All structural engineering is performed strictly according to Eurocodes (EN 1990, EN 1991, EN 1993, EN 1998) including project-specific National Annex parameters for local snow, wind, and seismic loads.
We offer five flexible delivery packages: Engineering Only, Supply Only (containerized flat-pack kit), Supply with On-Site Supervision, Complete Frame Installation, and Turnkey Project Delivery in eligible regions.
Components are precision roll-formed or cut, permanent piece-marked, and packed in dense weather-protected flat-pack bundles optimized for 40ft High Cube containers, accompanied by detailed 3D packing lists and assembly manuals.
Submit your project location, building dimensions (width, length, eave height), intended use, and any available architectural drawings or sketches via our 5-step RFQ form. Our engineering team reviews the submission and responds within 24–48 hours.
Submit your project dimensions, drawings or requirements for an engineering review and itemized quote within 24–48 hours.